Subaru Legacy

since 1990-1998 release

Repair and operation of the car



Subaru of Legasi
+ 1.1. Identification numbers
+ 2. Maintenance
+ 3. Engines
+ 4. Heating, ventilation
+ 5. Fuel system
- 6. Exhaust system
   6.1. Service of final system
   - 6.2. Reduction of toxicity of exhaust gases and management of operation of the engine
      6.2.1. Technical characteristics
      6.2.2. System of self-diagnostics (OBD) and codes
      6.2.3. Block of electronic control (ECM)
      6.2.4. Sensor of temperature of cooling liquid
      6.2.5. Sensor of provision of a butterfly valve
      6.2.6. Sensors of a cranked shaft, camshaft, car speed
      6.2.7. Oxygen sensor
      6.2.8. Air stream sensor
      6.2.9. Detonation sensor
      6.2.10. Pressure sensor in an inlet collector
      6.2.11. Replacement of the sensor of temperature of cooling liquid
      6.2.12. Replacement of the sensor of a stream of air
      6.2.13. Replacement of the sensor of oxygen
      6.2.14. Replacement of the sensor of provision of a butterfly valve
      6.2.15. Replacement of the sensor of an angle of rotation of a cranked shaft
      6.2.16. Replacement of the sensor of provision of a camshaft
      6.2.17. Replacement of the sensor of a detonation
      6.2.18. Replacement of the sensor of speed of the car
      6.2.19. Replacement of the sensor of pressure
      6.2.20. System of repeated burning of exhaust gases (EGR)
      6.2.21. System of catching of vapors of fuel (EVAP)
      6.2.22. System of compulsory ventilation of a case (PCV)
      6.2.23. Catalyst
+ 7. Systems of start, ignition
+ 8. Transmissions
+ 9. Coupling, shaft
+ 10. Brake system
+ 11. Suspension bracket
+ 12. Steering
+ 13. Body
+ 14. Electric equipment


3a942d17

6.2.17. Replacement of the sensor of a detonation

GENERAL INFORMATION

Prevention

Make replacement of the sensor of a detonation on the cold engine.


The sensor of a detonation is located under an inlet collector on the left back part of the engine.

PERFORMANCE ORDER
1. For access to the sensor of a detonation remove an inlet collector.
2. Merge cooling liquid from the cooling system.
3. Disconnect the electric socket from the sensor.
4. Unscrew the detonation sensor from the block of cylinders of the engine.
5. Before installation of the new sensor of a detonation on a carving of the new sensor apply a thin film of sealant.
6. Further installation is made in sequence, the return to removal.